Call to see how we can help you

01926 451744

Wanner G15 HydraCell Pump Pumps and Equipment Logo  
G15 pump
Unit
PSI
Bar
RPM
GPM
L/min
revs / gal
revs / litre
D/G 15/17-X
1000
70
1450
13.4
50
109
28.8
 
1500
100
1450
13.0
48
112
29.6
 
2000
140
1450
12.7
48
114
30.2
 
2500
170
1150
10.3
39
112
29.6
D/G 15/17-E
1000
70
1750
15.1
57
116
30.6
 
1500
100
1750
14.1
53
124
32.8
 
2000
140
1450
11.5
44
126
33.3
 
2500
170
1150
9.4
35
122
32.2
Maximum Inlet Pressure = 500 PSI (35 bar)
Pressure Variable to
2500 PSI (170 bar) at 1200 rpm
2000 PSI (140 bar) at 1450 rpm

Information kindly supplied by Wanner Engineering Inc.

Process Division:
Turnkey project engineering based on pump solutions:

- Consultancy
- Design
- Supply
- Manufacture
- Installation
- Project management