01926 451 744

Wanner Hydra-Cell – High pressure pumps / type G15

G-15 pump

Unit PSI bar RPM GPM L/min revs/gal revs/litre
D/G 15/17-X 1000 70 1450 13.4 50 109 28.8
1500 100 1450 13.0 48 112 29.6
2000 140 1450 12.7 48 114 30.2
2500 170 1150 10.3 39 112 29.6
D/G 15/17-E  1000  70 1750 15.1 57 116 30.6
1500 100 1750 14.1 53 124 32.8
2000 140 1450 11.5 44 126 33.3
2500 170 1150 9.4 35 122 32.2
Maximum Inlet Pressure = 500 PSI (35 bar)
Pressure Variable to
2500 PSI (170 bar) at 1200 rpm
2000 PSI (140 bar) at 1450 rpm